Impeller flow meter
FSseries 150¡î high temperature fluid corresponding
- This flow meter can measure fluid of 0 ~ 150¡î.
- Equipped with a cooling fan.
- This flow meter Type FS-series is used for measuring flow rate at high accuracy.
- Microprocessor processing technique make it possible to sense the measuring value very precisely.
- The result of measuring outputs to external terminal as analog value and is shown as digital value on LCD.
Further the result of displayed data compares the reference value to detect alarm signal,
- which output to "Open Collector" terminal and turns the LED on.
- Applicable models: FS-S / FS-AR / FS-N
- Each specification, the same as the standard.
<A cooling fan>Power supply---DC 24V¡Þ10%, Consumption current---80mA
Contact us for CAD data and instructions. *
Descriptions are based on Japanese Industrial Standards (JIS)
|
Specifications |
Model |
FS-3S-¢¢-B-¢¢Ž°¢¢-¢¢Ž°¢¢ |
FS-10S-¢¢-B-¢¢Ž°¢¢-¢¢Ž°¢¢ |
FS-30S-¢¢-B-¢¢Ž°¢¢-¢¢Ž°¢¢ |
Rated flow range |
0.5-3.0 L/min |
1.5-10.0 L/min |
5.0-30.0 L/min |
Aplicable fluid |
Industrial water, water,high temperature water |
Maximum working pressure |
1.0 MPa *1 |
Fluid temperature |
0-150C¡ë (No freezing, no dewing) |
Operating temperature |
0-40C¡ë (No freezing, no dewing) |
Power supply
voltage |
Meterunit |
24VDC¡Þ10% or 12VDC¡Þ5% *2 |
Fan |
24VDC¡Þ10% or 12VDC¡Þ5% |
Cable |
Meter unit |
AWM20276(6core / 0.2mÖ / 500mm) |
Fan |
UL Style 1007(Insulated cable, 2core / AWG26 / 300mm) |
Analog output |
0-10VDC(Voltage output) or 4-20mA(Current output) *3 |
Alarm output |
Max.40VDC/100mA A or B open-collector output *4 |
Current
consumption |
Meter unit |
Max.20mA(Voltage output) ,max.40mA(Current output) |
Fan |
80mA when 24VDC,140mA when 12VDC |
Wetted material |
SCS14, Fluorine resin, Ceramic, Fluorine rubber |
Connection material |
SCS14(equivalent to stainless steel 316) |
Connection size |
Rc3/8(Optional:Rc1/2,Rc1/4) *5 |
Orifice diameter |
¦Õ5 |
¦Õ7.2 |
¦Õ10 |
Mounting position |
Free |
Flow direction |
Both directions |
Weight |
Aprrox. 580g |
Construction |
Water drip-proof against electronic circuit |
Flow rate
measurement |
Accuracy |
¡Þ2.5%(F.S.) *6 |
Analog output |
Voltage output |
0-10VDC (over 3k¦¸load) |
Current output |
4-20£íADC (under300¦¸load) |
Flow rate display |
2 digits LCD with every 1 pitch |
3 digits LCD with every 1 pitch |
Flow display |
Constant scrolling LCD at 3 points |
Alarm
display |
Lighting |
If alarm set value is regarded as A L/min., |
Ž¥Green lighting:1.2¡ßA or more
¡¦Yellow lighting:(1-1.2)¡ßA
¡¦Red lighting:A or less |
¡¦Green lighting:1.2¡ßA or more
¡¦Yellow lighting:(1-1.2)¡ßA
¡¦Red lighting:A or less |
¡¦Green lighting:1.1¡ßA or more
¡¦Yellow lighting:(1-1.1)¡ßA
¡¦Red lighting:A or less |
Power down display |
1blinking point LCD on power supply at 75% of the power supply. |
*1 Pressure measured at 20¡î of fluid temperature is 1.0MPa.
*2 Power supply is transmitted of either 12VDC or 24VDC at the time of the order.
For the supply voltage of the cable for fan, the same specification as the meter unit is used.
*3 Analog output is transmitted of either voltage or current output at the time of the order.
*4 Alarm output is set at the time of the order , 3S = 2.0L/min, 10S = 6.0L/min, and 30S = 20.0L/min.
*5 In the case of 30S, connection size Rc1/4 can not be selected.
*6 In the case of FS-10S, Accuracy measured at 100 - 150¡î of water is ¡Þ2.5% (F.S.).
How to Order has a different model type.
If you have any query regarding our products or services, please feel free to contact us.
TEL: +81-42 756 7567
FAX: +81-42 752 2004
Email: info@rgl.co.jp