impeller flow meter FSseries 150¡î high temperature fluid correnponding
 

¥È¥Ã¥× > ¡üEnglish > Fluid Equipment > ±©º¬¼Ö¼°Î®ÎÌ·× > Impeller flow meter FSseries 150¡î high temperature fluid correspoding

Impeller flow meter

FSseries 150¡î high temperature fluid corresponding

  
 

  1. FS¥·¥ê¡¼¥º¹â²¹ÂбþThis flow meter can measure fluid of 0 ~ 150¡î.
  2. Equipped with a cooling fan.
  3. This flow meter Type FS-series is used for measuring flow rate at high accuracy.
  4. Microprocessor processing technique make it possible to sense the measuring value very precisely.
  5. The result of measuring outputs to external terminal as analog value and is shown as digital value on LCD.
    Further the result of displayed data compares the reference value to detect alarm signal,
  6. which output to "Open Collector" terminal and turns the LED on.
  7. Applicable models: FS-S / FS-AR / FS-N
  8. Each specification, the same as the standard.
<A cooling fan>Power supply---DC 24V¡Þ10%, Consumption current---80mA
Contact us for CAD data and instructions.  *
Descriptions are based on Japanese Industrial Standards (JIS)
 
Specifications
Model    FS-3S-¢¢-B-¢¢Ž°¢¢-¢¢Ž°¢¢ FS-10S-¢¢-B-¢¢Ž°¢¢-¢¢Ž°¢¢ FS-30S-¢¢-B-¢¢Ž°¢¢-¢¢Ž°¢¢
Rated flow range    0.5-3.0 L/min 1.5-10.0 L/min 5.0-30.0 L/min
Aplicable fluid      Industrial water, water,high temperature water
Maximum working pressure      1.0 MPa  *1
Fluid temperature      0-150C¡ë (No freezing, no dewing)
Operating temperature      0-40C¡ë  (No freezing, no dewing)
Power supply
voltage
 
Meterunit  24VDC¡Þ10% or 12VDC¡Þ5%  *2
Fan  24VDC¡Þ10% or 12VDC¡Þ5%
Cable Meter unit  AWM20276(6core / 0.2m­Ö / 500mm)
Fan  UL Style 1007(Insulated cable, 2core / AWG26 / 300mm)
Analog output   0-10VDC(Voltage output) or 4-20mA(Current output)  *3
Alarm output   Max.40VDC/100mA    A or B open-collector output  *4
Current
consumption
Meter unit  Max.20mA(Voltage output) ,max.40mA(Current output)
Fan  80mA when 24VDC,140mA when 12VDC
Wetted material     SCS14, Fluorine resin, Ceramic, Fluorine rubber
Connection material     SCS14(equivalent to stainless steel 316)
Connection size    Rc3/8(Optional:Rc1/2,Rc1/4*5
Orifice diameter   ¦Õ5 ¦Õ7.2 ¦Õ10
Mounting position      Free
Flow direction      Both directions
Weight     Aprrox. 580g
Construction     Water drip-proof against electronic circuit
Flow rate
measurement
Accuracy  ¡Þ2.5%(F.S.)  *6
Analog output Voltage output  0-10VDC (over 3k¦¸load)
Current output  4-20£íADC (under300¦¸load)
Flow rate display  2 digits LCD with every 1 pitch 3 digits LCD with every 1 pitch
Flow display  Constant scrolling LCD at 3 points
Alarm
display
Lighting If alarm set value is regarded as A L/min.,
Ž¥Green lighting:1.2¡ßA or more
¡¦Yellow lighting:(1-1.2)¡ßA
¡¦Red lighting:A or less
¡¦Green lighting:1.2¡ßA or more
¡¦Yellow lighting:(1-1.2)¡ßA
¡¦Red lighting:A or less
¡¦Green lighting:1.1¡ßA or more
¡¦Yellow lighting:(1-1.1)¡ßA
¡¦Red lighting:A or less
Power down display  1blinking point LCD on power supply at 75% of the power supply.
*1 Pressure measured at 20¡î of fluid temperature is 1.0MPa.
*2 Power supply is transmitted of either 12VDC or 24VDC at the time of the order.
For the supply voltage of the cable for fan, the same specification as the meter unit is used.
*3 Analog output is transmitted of either voltage or current output at the time of the order.
*4 Alarm output is set at the time of the order , 3S = 2.0L/min, 10S = 6.0L/min, and 30S = 20.0L/min.
*5 In the case of 30S, connection size Rc1/4 can not be selected.
*6 In the case of FS-10S, Accuracy measured at 100 - 150¡î of water is ¡Þ2.5% (F.S.).
 

Oder form
Model    FS-S FS-AR FS-N


How to Order has a different model type.
If you have any query regarding our products or services, please feel free to contact us.


           TEL: +81-42 756 7567
           FAX: +81-42 752 2004
           Email: info@rgl.co.jp

 